3.3.4 RS-485 Connector Definition
RS-485 is the interface that communicates the Dome Camera and its control
device. Please connect the control keyboard to the Dome Camera through
the terminal block. The recommended cables for RS-485 communication are
CAT 5 cables; maximum cable length for over 24-gauge wire is 4000 feet
(1219 meters). If the total cable length exceeds 4000 feet, using a repeater to
maintain the signals is recommended. Please refer to the figure and table
below for pin defination and wiring.
3.3.5 Cable Wiring and Connection
Users may need to conduct cable wiring when: (1) Connecting self-provided
cords to the connector housing instead of using the equipped data cable or (2)
Connecting alarm input and output devices. The table follows will illustrate the
way to wire cords into the connector housing.
Pin
Corresponding Pins
(22-Pin Connector)
Definition
1 7,10 T+, R+ (D+)
2~4 Reserved
5 8,9 T-, R- (D-)